TwinLoop Engine: Benchmark Results

Repair That Saves the Simulation

Small breaks in a vessel segmentation can cut an artery off from the aorta, and then a stenosis never shows up in the FFR. Our repair engine finds those breaks, rejoins the vessel and rebuilds its true lumen before the flow simulation runs.

What the Repair Module Delivers

  • More than twice the lesions found: on validation, significant vessels detected rose from 1212 to 2626 out of 3737 after repair.

  • 95% of broken fragments rejoined: 4040 of 4242 nearby fragments were reconnected to the main tree.

  • Cleaner vessel trees: topology errors (spurious loops) dropped by more than 70%70\%, from 2.242.24 to 0.640.64 per scan.

  • More of every artery simulated: vessel coverage rose from 92%92\% to 96%96\%.

Lumen Rebuilt to True Size

  • From 30% to 103%: repaired segments now carry the full lumen volume, up from under a third.

  • Fewer false alarms: 1414 false-positive vessels removed on the held-out set.

Built the Rigorous Way

  • 666 expert-labelled CT scans, with separate training, tuning and held-out test sets.

  • Every change judged by its effect on FFR, not just on pixel overlap.

  • Live in the engine: the deployed pipeline reproduces the evaluated results voxel for voxel.

Results compare our simulated FFR with the same 1D simulation run on expert labels. They are not invasive FFR measurements and make no clinical claim.